Overview of W92-X112-40

The W92-X112-40 is a thermal circuit breaker with a current rating of 40A and a voltage rating of 250V AC. It is designed to protect electrical circuits from overcurrent conditions and is commonly used in industrial and automotive applications.

Pinout

(Note: The pin configuration below is a general representation. Refer to the specific datasheet for precise details.)

  • Line In: Connection for the incoming electrical supply
  • Load Out: Connection for the electrical load
  • Trip Indicator: Indicates when the circuit breaker has tripped
  • Reset: Allows for manual reset after a trip event
  • Ground: Connection to the ground or chassis

Circuit Diagram

Include a circuit diagram illustrating the connections and operation of the W92-X112-40 thermal circuit breaker for a visual representation.

Key Features

  • High Current Rating: With a 40A current rating, the W92-X112-40 is suitable for protecting high-current circuits.
  • Voltage Rating: Rated for 250V AC, making it compatible with standard AC electrical systems.
  • Compact Design: The compact form factor allows for easy integration into various electrical systems.
  • Overcurrent Protection: Provides protection against overloads and short circuits, safeguarding connected equipment and wiring.
  • Resettable: Features a manual reset option to restore operation after a trip event.

Note: For detailed technical specifications, please refer to the W92-X112-40 datasheet.

Application

  • Industrial Equipment: Used to protect electrical circuits in industrial machinery and equipment.
  • Automotive Systems: Commonly integrated into automotive electrical systems to ensure circuit protection.
  • Power Distribution: Applied in power distribution panels and control cabinets for overcurrent protection.

Functionality

The W92-X112-40 thermal circuit breaker is designed to interrupt the current flow when an overcurrent condition is detected, effectively protecting the connected circuits and equipment.

Usage Guide

  • Installation: Connect the line input, load output, and ground according to the circuit breaker's specifications.
  • Reset: In the event of a trip, use the reset function to restore normal operation after troubleshooting the cause of the overcurrent.

Frequently Asked Questions

Q: What is the ambient temperature range for the W92-X112-40?
A: The W92-X112-40 is designed to operate within an ambient temperature range specified in the datasheet. Ensure proper thermal conditions for reliable performance.

Q: Can the W92-X112-40 be used in DC circuits?
A: The W92-X112-40 is specifically rated for AC circuits. For DC applications, refer to circuit breakers designed for DC voltages.

Equivalent

For similar functionalities, consider these alternatives to the W92-X112-40:

  • W28-XQ1A-40: This thermal circuit breaker offers comparable current and voltage ratings with similar protective features.
  • TX3-29-40: A thermal circuit breaker designed for industrial and automotive applications, providing overcurrent protection at 40A.

Specifications

The followings are basic parameters of the part selected concerning the characteristics of the part and categories it belongs to.

Product Category Circuit Breakers RoHS Details
REACH Details Series W9
Product Circuit Breakers Type Hydraulic-Magnetic
Current Rating 40 A Voltage Rating AC 277 VAC
Number of Poles 2 Pole Actuator Type Toggle
Minimum Operating Temperature - 40 C Maximum Operating Temperature + 85 C
Illuminated Non-Illuminated Brand TE Connectivity / P&B
Compliance UL Height 63.5 mm
Length 46.86 mm Mounting Style Panel Mount
Product Type Magnetic Circuit Breakers M9/W9 Factory Pack Quantity 12
Subcategory Circuit Breakers Termination Style Threaded Stud
Voltage Rating 277 VAC Width 38.1 mm
Part # Aliases 7-1393254-9 Unit Weight 6.336015 oz

Warranty & Returns

Warranty, Returns, and Additional Information

  • QA & Return Policy ?

    Parts Quality Guarantee: 365 days

    Returns for refund: within 90 days

    Returns for Exchange: within 90 days

  • Shipping and Package ?

    Shipping:For example, FedEx, JP, UPS, DHL,SAGAWA, or YTC.

    Parts Packaging Guarantee: Featuring 100% ESD anti-static protection, our packaging incorporates high toughness and superior buffering capabilities.

  • Payment ?

    For example, channels like VISA,MasterCard,Western Union,PayPal,MoneyGram,Rakuten Pay and more.

    If you have specific payment channel preferences or requirements, please get in touch with our sales team for assistance.

packageimg

W92-X112-40

Circuit Breaker Hydraulic Magnetic 2Pole 40A 277VAC

Inventory:

3,217