MAX30112EWG+T
MAX30112EWG+T is an Analog Front End (AFE) suitable for various applications
Inventory:6,109
- 90-day after-sales guarantee
- 365 Days Quality Guarantee
- Genuine Product Guarantee
- 7*24 hours service quarantee
-
Part Number : MAX30112EWG+T
-
Package/Case : WLCSP-24
-
Manufacturer : Analog Devices
-
Datesheet : MAX30112EWG+T DataSheet (PDF)
Overview of MAX30112EWG+T
With its advanced technology and superior design, the MAX30112EWG+T stands out as the ideal choice for professionals seeking a reliable, high-performance solution for pulse oximetry and heart rate monitoring. Its precision and efficiency make it a valuable asset in the field of healthcare and wearable technology
Key Features
- Reflective or Transmissive Heart Rate, Heart Rate Variability, or SpO2 Monitoring
- Transmit Section
- Two 8-bit LED Current DACs
- Four Current Ranges 50mA, 100mA, 150mA, 200mA
- Low Noise Current Sources for High Peak Transmit to Receive Dynamic Range
- Low 160mV Dropout to Support Direct Drive From Rechargeable Li Battery
- High Output Impedance and High Supply Rejection to Support Unregulated Supply or Direct Drive From Boost Switcher Supply
- Receive Section
- 19-bit Optical ADC Path to Support the Lowest Perfusions Situations
- Low 25pA-RMS Input Referred Noise to Minimize LED Power Under Most Conditions
- High Ambient Light Input Range of 200μA and to Support Extraction of HRM Signal in the Most Adverse Lighting Conditions
- Built-in Front And Back End Ambient Light Cancellation, Improving Rejection and Eliminating System Complexity of Dealing with Ambient Light
- Short Exposure Pulse Widths of 52μs, 104μs, 206μs, 417μs for Efficient Uses of LED Light
- Multiple Sample Rate Options from 20sps to 3.2ksps
- Ultra-Low-Power Operation for Mobile and Body-Wearable Device
- Dynamic Power Down Modes to 100sps for Low-Power Consumption
- Full AFE Power Consumption of Less Than 25μA (typ) at 25sps
- Large 32 Sample FIFO to Support Batch Processing in the Microcontroller
- Variety of System Monitors Mappable to Interrupts to Off-Load System Monitoring Functions From the Microcontroller
- Low Shutdown Current = 1.4μA (typ)
- I2C interface
- Supports a Single 1.8V Supply with Separate 3.1V to 5.25V LED Supply
- Miniature 2.8mm x 2.0mm, 6x4, 0.4mm Ball Pitch WLP Package
- -40°C to +85°C Operating Temperature Range
Application
- Breathable Workout Bands
- High-Tech Exercise Gear
- Performance Monitoring Tools
Specifications
The followings are basic parameters of the part selected concerning the characteristics of the part and categories it belongs to.
Product Category | Biometric Sensors | RoHS | True |
Product | Oximeter/Heart Rate Monitors | Operating Supply Current | 241 uA |
Mounting Style | SMD/SMT | Maximum Operating Temperature | + 85 C |
Minimum Operating Temperature | - 40 C | Operating Supply Voltage | 1.7 V to 2 V |
Brand | Analog Devices / Maxim Integrated | Package / Case | WLP-24 |
Product Type | Biomedical Sensors | Series | MAX30112 |
Factory Pack Quantity | 2500 | Subcategory | Sensors |
Supply Voltage - Max | 2 V | Supply Voltage - Min | 1.7 V |
Unit Weight | 0.001658 oz |
Warranty & Returns
Warranty, Returns, and Additional Information
-
QA & Return Policy ?
Parts Quality Guarantee: 365 days
Returns for refund: within 90 days
Returns for Exchange: within 90 days
-
Shipping and Package ?
Shipping:For example, FedEx, JP, UPS, DHL,SAGAWA, or YTC.
Parts Packaging Guarantee: Featuring 100% ESD anti-static protection, our packaging incorporates high toughness and superior buffering capabilities.
-
Payment ?
For example, channels like VISA,MasterCard,Western Union,PayPal,MoneyGram,Rakuten Pay and more.
If you have specific payment channel preferences or requirements, please get in touch with our sales team for assistance.
MAX30101EFD+T
MAX30101EFD+T SENSOR OXIMETER/HEART RATE I2C
MAX30105EFD+
Smoke Detectors Optical Sensor for Fire Alarm Apps
MAX86141ENP+
Biometric Sensors Optical AFE for HR on Wrist Apps
MAX25205EQP/VY+T
Sensor Interface 400 um Lensless Gesture recognition IC for Automotive
MAX86916EFD+T
Biometric Sensors Heart-Rate and Blood Oxygen Bio-Sensor
MAX86174AENE+
Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health
MAX30105EFD+
Smoke Detectors Optical Sensor for Fire Alarm Apps
TSL1412S
TSL1412S product
TSL208R
Light To Frequency & Light To Voltage Linear Array 200 DPI
TSL1401CS-LF
TSL1401CS-LF is a linear sensor array capable of converting light into frequency and voltage signals
BH1790GLC-E2
Tape and Reel packaged BH1790GLC-E2: Optical sensor tailored for heart rate monitoring applications
E3A2-R3M4
Slim Sensor 10 ft Sensing 24-240VAC/12-240VDC SPDT Relay Output Light/Dark Operate Output
MAX30112EWG+T
MAX30112EWG+T is an Analog Front End (AFE) suitable for various applications
Inventory:
6,109Warranty & Returns
After Sales Service
What after-sales service can be provided?
We provide an extended quality assurance period of 365 days for all components we offer. If a return or exchange becomes essential, kindly adhere to these guidelines:
·Initiate the request within 90 days after the item's shipment date.
·Coordinate the return or exchange with our team.
·Keep the items in their original condition as delivered.
·Please be aware that the feasibility of returning or exchanging items is contingent upon an evaluation of their actual state upon return.
Shipping
What channels of transportation of goods does the website support?
We usually send out our orders during business days using FedEx, SF, UPS, or DHL. We're also here to assist with alternative shipping options. Should you require additional information about shipping particulars or expenses, please don't hesitate to get in touch with us.
Package
How to ensure that the parts will be intact during transportation?
The items we ship will be packaged in anti-static bags, ensuring ESD anti-static protection, while the outer packaging boasts exceptional durability and sealing. We offer packaging options like Tape and Reel, Cut Tape, Tube, or Tray to suit your needs.
Payment
Which payment methods can be used to pay for goods
Accepted payment methods commonly encompass VISA, MasterCard, UnionPay, Western Union, PayPal, and various other options.
Should you have a particular payment preference or wish to seek information on rates and other specifics, please feel free to reach out to us.